Loctite
Washer
BHSCS/
Loctite
End Cap
Spacer
Figure 3
B. Unplug the heart rate cables. See Figure 4.
Left Input Handle
BHSCS/
Loctite
Washer
Heart Rate
Cables
Figure 4
C. Using two 7/32" Allen wrenches, remove the
BHSCS and washer from the pivot shaft.
See Figure 4.
D. Slide the pivot shaft through main frame
opening to remove input handles. See
Figure 4.
E. Set input handles aside (they will be
reattached later).
6. Remove the front cover.
A. Using a Phillips
screwdriver, remove
the four screws
securing the front
cover. See Figure 5.
B. Remove front cover.
Input
Handle
Grease
S-Link
Right Input Handle
Opening
Pivot Shaft
Washer
Grease
BHSCS/
Loctite
Loctite
Front
Cover
Screws
(4)
Figure 5
7. Remove top cover.
A. Using a Phillips screwdriver, remove the
screw securing the top cover. See Figure 6.
Figure 6
B. Remove top cover.
8. Remove upper side covers.
A. Using a Phillips screwdriver, remove the
screw securing each of the upper side covers.
See Figure 7.
Locking
Connectors
Upper Left
Side Cover
Figure 7
B. Remove upper side covers.
9. Remove both lower side covers.
A. Using a Phillips head screwdriver, remove the
four screws securing each of the lower side
covers. See Figure 8.
Top Cover
Screw
Screw

Hide quick links: