Intermec 3440 User Manual page 95

Bar code label printer
Hide thumbs Also See for 3440:
Table of Contents

Advertisement

1233*
Error Codes Sent to the Host (continued)
Code
Problem
28
Invalid UDC transmission syntax.
32
Non-immediate command or data received
after buffer full.
33
Invalid field delimiters.
34
Invalid escape command.
35
Invalid data shift command.
36
Invalid or undefined format number.
37
Insufficient room in RAM to print format.
38
Invalid or undefined field number.
41
Syntax error for program commands.
42
Insufficient room in RAM to store format.
43
Too many fields in label format.
46
Undefined statement.
52
Invalid UDC/UDF bitmap cell
height/width or intercharacter space.
53
Insufficient room in RAM to store UDC or
UDF.
54
Invalid UDC command syntax.
FranklinGothic Helv Condensed
Solution
Check the UDC transmission syntax. The
correct syntax is <ESC>un with n ranging
from 0 to 99.
Allow the printer to empty the buffer
contents before sending commands or data.
Check for all pairs of field delimiters and
make sure both are numeric, or both are
alphanumeric.
Correct the escape command syntax.
Correct the shift command syntax.
Verify that the format numbers are between
0 and 99.
Reduce the number of data fields in the
format.
Verify the field number in the label format.
Check the program command for proper
syntax.
Empty the buffer contents. If the format still
does not fit, delete some fields or other data
from the format. You may have to remove
or reduce the UDCs, formats, or fonts if
necessary.
You can use up to 200 fields in a format and
each field can use up to 3000 characters.
Reduce field size or delete some fields.
Check the statement syntax.
Verify that cell heights are between 1 and
1999, cell widths are between 1 and 800, and
the intercharacter space is between 0 and
399.
Remove or reduce formats, fonts, or UDCs.
Correct the UDC command syntax.