Preparing for Operation
n022

Deceleration Time 2

Setting range
0.0 to 3,600
• Acceleration time and deceleration time can be set with n019 to n022.
• The acceleration/deceleration time switching command must be selected to use acceleration time 2
and deceleration time 2. Refer to page 3-66 , Multi-function Inputs (n035 to n039) for details.
Set Values
• Acceleration time: The time required for the output frequency to be 100% from 0% of the maximum
frequency.
• Deceleration time: The time required for the output frequency to be 0% from 100% of the maximum
frequency.
• Acceleration time 2 and deceleration time 2 will be available if the acceleration/deceleration time
switching command is set.
n023

S-shaped Characteristic Time Selection

Setting range
0, 1, 2, and 3
• The shock of the mechanical system resulting the moment the mechanical system starts or stops can
be reduced with the S-shaped acceleration and deceleration.
Set Values
Set value
0
No s-shaped characteristic time
1
S-shaped characteristic time: 0.2 s
2
S-shaped characteristic time: 0.5 s
3
S-shaped characteristic time: 1.0 s
Note The acceleration time and deceleration time of the Inverter will increase by the S-shaped charac-
teristic time set with n023.
Output
frequency
n024
Unit of Frequency Reference
Setting range
0 to 3,999
3-62
Unit
s
Unit
---
Description
With no S-shaped
characteristic
S: S-shaped characteristic time
Unit
---
Chapter 3
Default setting
10.0
Default setting
1
Time
Default setting
0