4-4 Communication Function
Register
No.
1440h
Not used
1441h
Thermal warning level
1442h
Alarm code selection
1443h
0-Hz detection level
1444h
Fin overheat warning level
4
1445h
to
Not used
144Ah
Communication speed
144Bh
selection
(Baud rate selection)
Communication station
144Ch
No. selection
Communication bit length
144Dh
selection
Communication parity
144Eh
selection
Communication stop bit
144Fh
selection
Communication error
1450h
selection
Communication error
1451h
timeout
1452h
Communication wait time
Communication method
1453h
selection
1454h
Not used
1455h
FV adjustment
1456h
FI adjustment
1457h
FE adjustment
1458h
Not used
1459h
Thermistor adjustment
145Ah
to
Not used
145Eh
145Fh
Not used
4-199
Function
Function name
code
⎯
C061
C062
C063
C064
⎯
C071
C072
C073
C074
C075
C076
C077
C078
C079
⎯
C081
C082
C083
⎯
C085
⎯
⎯
R/W
Monitor and setting parameters
⎯
R/W
0 to 100
0: Disabled
R/W
1: 3 bits
2: 4 bits
R/W
0 to 10000
R/W
0 to 200
⎯
2: Loop-back test
3: 2400 bps
R/W
4: 4800 bps
5: 9600 bps
6: 19200 bps
R/W
1 to 32
7: 7 bits
R/W
8: 8 bits
0: No parity
R/W
1: Even
2: Odd
1: 1 bit
R/W
2: 2 bits
0: Trip
1: Trip after deceleration stop
R/W
2: Ignore
3: Free-run stop
4: Deceleration stop
R/W
0 to 9999
R/W
0 to 1000
0: ASCII
R/W
1: ModBus-RTU
⎯
R/W
0 to 65530
R/W
0 to 65530
R/W
0 to 65530
⎯
R/W
0 to 10000
⎯
⎯
Resolution
⎯
1 [%]
⎯
0.01
[Hz]
°
1 [
C]
⎯
⎯
⎯
⎯
⎯
⎯
⎯
0.01 [s]
1 [ms]
⎯
⎯
1
1
1
⎯
0.1
⎯
⎯