Omron SYSDRIVE RX Series User Manual page 234

High-function general-purpose inverter
Table of Contents

Advertisement

4-3 Functions When Option PG Board (3G3AX-PG01) Is Used
Note: Below are the block diagrams of the electronic gear function.
P019 = 00 (FB)
4
P019 = 01 (REF)
*1. It is recommended that position control feedfoward gain adjustment should be started with P022 = 2.00. To
reduce the position deviation between the main and sub motors, increase the feedforward gain. If motor
hunting occurs, reduce the feedforward gain.
*2. It is recommended that position loop gain adjustment should be started with P023 = 2.00. To increase
positioning accuracy and holding power, increase the position loop gain. If an increased position loop gain
causes hunting, reduce the position loop gain.
*3. Make sure that the N/D setting is within the range of 1/50 ≤ N/D ≤ 20.
(N: Electronic gear ratio numerator [P020], D: Electronic gear ratio denominator [P021])
4-125
First-order lag filter
1
1+sT
Position loop gain
Position
command
N
Electronic gear
D
Position feedback
First-order lag filter
1
1+sT
Electronic gear
Position
N
command
D
Position feedback
Position control feedforward gain
P022
Speed
P023
command
Position control feedforward gain
P022
Position loop gain
Speed
P023
command

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents