Omron SYSDRIVE RX Series User Manual page 115

High-function general-purpose inverter
Table of Contents

Advertisement

Position Command Monitor (Absolute Position Control Mode) [d029]
You can monitor a position command in absolute position control mode.
Note: This monitor is enabled only when V2 control mode selection P012 is set to "02" or "03" in
sensor vector control mode.
Current Position Monitor (Absolute Position Control Mode) [d030]
You can monitor the current position in absolute position control mode.
Note: This monitor is enabled only when V2 control mode selection P012 is set to "02" or "03" in
sensor vector control mode.
Fault Frequency Monitor [d080]
Displays the number of times the Inverter has tripped.
(Display)
0. to 9999.
1000 to 6553 : Displays in increments of 10 times.
Fault Monitors 1 to 6 [d081] to [d086]
Displays the details of the last six trips.
The most recent trip is displayed on trip monitor 1.
(Display)
(1) Factor (Displays any of E01 to E79.)
(2) Output frequency (Hz) at the time of tripping
(3) Output current (A) at the time of tripping
(4) Main circuit DC voltage (V) at the time of tripping
(5) Total RUN time (h) before the trip
(6) Total power ON time (h) before the trip
* Refer to "Error Code List" (page 5-1).
(Trip Monitor Display Sequence)
*
(1) Trip factor
dk0k8k1
ek0k7.2
* Displays
_k_k_k_
: Displays in increments of 1 time.
*
(2) Trip frequency
(3) Trip current
6k0.0k0
4.0k0
if there has been no trip.
4-1 Monitor Mode
(4) Trip main circuit
(5) Total RUN time
DC voltage
4k0k0.2
1k5.
4
(6) Power ON time
1k8.
4-6