10 Input S/N:
L
A 022-4064
3
Serial #
Loop #
If the serial and loop number combination is already present in the system, you will hear a single
long beep from the keypad. If this happens, the system will not display the serial number, but will
wait for a transmission from another transmitter or transmitter loop input.
10 Confirmed
A022-4064
3
At any time during this step, you may press [ ] on the keypad or the upper left-hand button of the
program tool if you are satisfied with the serial and loop number combination that has been
enrolled, regardless of whether or not the enrolled input has been "confirmed." This will ready the
system to enroll the next transmitter.
If the incorrect transmitter has been enrolled, press [#] on the keypad or the upper right-hand
button of the program tool to delete the serial number and return to the "LEARN S/N" prompt. The
keypad will emit a single long beep to verify pressing of the upper right-hand button. Then, press 1
(Yes) or press the upper left-hand button of the program tool (a single short beep will verify the
system is ready for enrolling) and re-activate the proper transmitter or transmitter loop input.
When you have finished programming all zones, test each using the system's Test mode. Do not
use the Transmitter ID Sniffer mode for this, as it will only check for transmission of one zone on a
particular transmitter, and NOT the zones assigned to each additional loop.
The system will enroll the serial number of the first
transmitter heard, add the loop number entered to this
serial number, display the serial and loop numbers, and
cause the keypad to beep twice.
6. The system will then enter an optional confirmation
mode so that the operation of the actual programmed
input can be confirmed. Activate the loop input or button
that corresponds to this zone. We recommend that you
confirm the programming of every transmitter
before proceeding to the next zone.
When the system sees activity on the appropriate input,
it will beep three times and display the confirmation
message. Press [ ] or the upper left-hand button of the
program tool when you are ready to enroll the next
transmitter.
7. The system will search for the next zone that does not have
a serial number associated with it. If one is found, the
keypad will display the prompt in step 5, along with the
appropriate zone number. Follow steps 5 and 6 for the
remaining wireless zones.
8. After all wireless zones have been displayed, whether
enrolled or not, the "Enter Zn Num." prompt will appear.
Enter 00 to exit the Sequential mode and return to Data
Field Programming mode.
Section 12: Sequential Mode