ADEMCO Vista-10SEa Installation And Setup Manual page 40

Vista-10sea
Hide thumbs Also See for Vista-10SEa:
Table of Contents

Advertisement

VISTA-10SEa Installation and Setup Guide
00 Input S/N:
A
X X X–X X X X
00 Input S/N:
A123-4567
Enter Zn Num.
(00 = Quit)
ZN ZT – RC I n: L
1 0 0 0 – 0 0 RF: 1
¬ Zone Number
1 0 Zo ne T yp e
P er imeter
Entry for Zone Type 03
1 0 Rep o r t Co d e
1 st 0 3 2 nd 1 2 3 C
6-8
L
L
3
10
Zone 10 entered 
0 3
shown
3. If you entered "1," the system will prompt for the unit's
serial number. Enter the program tool's serial number
using one of the following methods:
a. Enter the 7-digit serial number for the transmitter.
or
b. Press any button on the transmitter. The keypad should
beep twice and display the serial number of the tool.
In this example, the serial number is A123-4567. Once
the program tool is enrolled, the upper left-hand button
of the tool can be pressed to ready the system for
enrolling a transmitter into the system.
Pressing the [#] key on the keypad will cause the system
to back up to the "Program Tool?" prompt.
The serial number for the program tool will remain
in the system only until the programming mode is
exited. (Entering 97 will not delete the tool.)
Press [ ] to continue.
4. Enter the zone number that you wish to program. As an
example, zone 10 is shown here.
Press [ ] to continue.
5. A display will appear showing a summary of that zone's
programming. If the zone is not programd, the display
will appear as shown here. If you are checking a zone's
programming, and it is programd satisfactorily, press [#]
to back up one step and enter another zone number, if
desired. Otherwise, press [ ] to continue.
6. Each zone must be assigned a zone type, which defines
the way in which the system responds to faults in that
zone. Enter the zone type desired (or change it, if
necessary). Available zone types are:
00 = Zone Not Used
01 = Entry/Exit #1, Burglary
02 = Not Used
03 = Perimeter
04 = Interior Follower
05 = Trouble Day/Alarm Night 22 = Disarm*
06 = 24 Hr Silent
07 = 24 Hr Audible
* These are special zone types used with 5800 Series
wireless pushbutton units that will arm the system in the
STAY or AWAY mode, or disarm the system, depending on
the selection made. A button programmed for these
functions will report to the central station the zone
number of the button as the user number that
armed/disarmed.
Press [ ] to continue.
7. Enter the report code. The report code consists of 2
hexadecimal digits, each consisting of 2 numeric digits.
For example, for a report code of "3C," enter [0][3] for "3"
and [1][2] for "C."
(Refer to Section 13: SYSTEM COMMUNICATION for
more information about report codes and report code
08 = 24 Hr Aux
09 = Fire
10 = Interior w/Delay
20 = Arm–Stay*
21 = Arm–Away*
23 = No Alarm Response
(e.g., Relay activation)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents