1. Make certain that all devices and sensors connected to the basic wired zones are not in a
faulted state. Doors and windows with contacts should be closed, PIRs should be covered
(use a cloth to mask them temporarily, if necessary).
2. Plug in the mains plugpack if you have not already done so.
3. With all basic wired zones intact, the alpha keypad connected to the system should
display:
If the keypad displays this:
press the [ ] key to display the faulted zone(s). Restore any faulted zone(s) as necessary.
(Also make sure that you have connected a 1000-ohm EOL resistor across the terminals
of any unused basic wired zones.)
When the "DISARMED/READY TO ARM" message is displayed, you can proceed to the
next step.
4. Fault and then restore every contact or sensor on each zone individually to ensure that it
is being monitored by the system. Each time a zone is faulted, the keypad should display
the number of the faulted zone. When each zone is restored, the "READY TO ARM"
message should appear again.
5. When you get the proper displays on the keypad(s), the basic wired zones in the system
are functioning properly.
DISARMED
READY T O ARM
DISARMED Pr es s
to s how faults
Section 4: Basic Wired Zones 1-6
4-5