Enter Zn Num.
(00 = Quit)
01
Default Zone Number 
after entering 56
Typical summary display
Zn ZT – RC
In
03 03 – 10
HW: –
¬ Zone Number
03 Zone Type
Perimeter
03
Zone Type 
00 = Zone Not Used
01 = Entry/Exit #1
02 = Entry/Exit # 2
03 = Perimeter
04 = Interior Follower
05 = Trouble Day/Alarm Night
06 = 24-Hr Silent
07 = 24-Hr Audible
You must enter 00 as the zone type for any wired zones that are not used.
03 Report Code
1st 03 2nd 12
Enter the first zone number that you wish to program (or
00 to exit zone programming). If you are starting with zone
1, leave as is and press [ ] to continue.
If you are programming another zone, enter the desired
zone number; e.g., 02, 03, etc. (zone 03 is shown in the next
display). Press [ ] to continue.
A summary display will appear, showing the present
status of that zone's programming.
L
Zn = zone number.
ZT = zone type.
RC = Report code for that zone.
In = input type of zone (HW will be displayed).
Values displayed are currently programmed values. The
summary display at the left shows the default values.
If it is programmed satisfactorily, press [#] to back up one
step and enter the next zone number.
If you want to change a zone's programming, press [ ]. A
prompt for zone type will appear.
Each zone must be assigned a zone type, which defines the
way in which the system responds to faults in that zone.
See "Response Type Definitions" section in the separate
Programming Guide for an explanation of each zone
type.
Enter the desired Zone Type code, from the list on the next
page.
The example on the left shows zone type "03" (Perimeter)
entered (this is the default for zone 3).
Zone Types
08 = 24-Hr Aux
09 = Fire
10 = Interior w/Delay
20 = Arm-Stay
21 = Arm-Away
22 = Disarm
23 = No Alarm
When the display shows the zone type you want, press [ ] to
continue.
The report code consists of 2 hexadecimal digits, each
consisting of 2 numerical digits. To enable a report, the
3C
first hex digit must be non-zero. Any code can be entered
for record purposes. Refer to Section 13: SYSTEM
COMMUNICATION for complete information on report
codes, if necessary.
Enter the desired report code and then press [ ] to
continue.
Section 4: Basic Wired Zones 1-6
o
5800
o
RF
o
Only
Response
4-3