Advertisement

Features Q.E.D. programming for quick
enrollment of devices.
N7227V1PRGD 4/97
VISTA-10

SECURITY SYSTEM

PROGRAMMING
SE
GUIDE

Advertisement

Table of Contents
loading

Summary of Contents for ADEMCO VISTA-10SE

  • Page 1: Security System

    Features Q.E.D. programming for quick enrollment of devices. VISTA-10 SECURITY SYSTEM PROGRAMMING GUIDE N7227V1PRGD 4/97...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Programming Form ....................3 Mechanics of Programming .................. 7 General Programming Information..............7 Entering the Programming Mode ............... 7 Programming a Data Field ................. 8 Reviewing a Data Field/Erasing an Entry in a Data Field ....... 8 Interactive Menu Mode Programming ( 56, 80, 81, 82, &...
  • Page 3: Programming Form

    VISTA-10 PROGRAMMING FORM Local programming requires the use of a 2-line Alpha keypad (e.g., 6139) connected to the keypad terminals on the control. To set all program fields to Ademco default values: Key Field Function Programmed Values ] = Default Value ––––––––...
  • Page 4 Alarms, Open/Close for Users 5 –25 † , 9 = All reports except Open/Close Troubles Can only be used if Primary reporting is Ademco Contact ID. † See field 47 in the DATA FIELD DESCRIPTIONS section. † 15 SEC DIALER DELAY (BURG) 0 = no;...
  • Page 5 A "0" ( not "#+10") in both boxes will disable the report. RF XMTR LOW BAT REPORT CODE With Ademco Contact ID Reporting: Enter any digit (other than CANCEL REPORT CODE "0") in the first box, to enable zone to report (entries in the second boxes will be ignored).
  • Page 6 See No entry required. AAV section in the Installation Instructions. 97 SETS ALL PROGRAM FIELDS TO ADEMCO 92 REPORTS PER ARMED PERIOD FACTORY DEFAULT VALUES. 0 = 10 max total alarm + alarm restore; 1 = unlimited OUTPUT RELAYS WORKSHEET FOR FIELDS 80 and 81.
  • Page 7: Mechanics Of Programming

    Programming can also be performed remotely from the installer’s office/home, using an IBM personal computer, a modem, using either Ademco’s V-Link ® downloading software (Rev. 4 or higher) or Ademco’s Compass Windows downloading software.
  • Page 8: Programming A Data Field

    5800 series transmitter serial numbers Loading Factory Defaults ( 97) To load the Ademco factory defaults, enter the programming mode, press 97, then exit the programming mode. Do not press 97 if you program new values in place of the factory defaults—...
  • Page 9: 5800 Series Transmitter Input Loop Identification

    5800 Series Transmitter Input Loop Identification • All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes. Each of the inputs requires its own programming zone (e.g., a 5804's four inputs require four programming zones).
  • Page 10: Alpha Vocabulary List (For Entering Zone Descriptors)

    ALPHA VOCABULARY LIST (For Entering Zone Descriptors) NOTE : Some words appearing in previously published lists have been deleted from the list below. Use only this list for selecting zone descriptors. (Word Space) • 057 DOOR • 106 LAUNDRY • 059 DOWN RADIO VALVE...
  • Page 11: Zone Response Type Definitions

    ZONE RESPONSE TYPE DEFINITIONS Type 00 Program a zone with this zone type if the zone is not used. Zone Not Used Type 01 This zone type provides entry delay whenever the zone is faulted if the control Entry/Exit Burglary is armed in the AWAY or STAY modes.
  • Page 12 Type 20 This is a special-purpose zone type used with 5800 series wireless pushbutton Arm–Stay units which will result in arming the system in the STAY mode when the zone is activated. Pushbutton units send zone number as a user number to central station when arming or disarming.
  • Page 13: Data Field Descriptions

    DATA FIELD DESCRIPTIONS The blank programming form in this manual should be used to record the data for this installation. The following is a list of all data fields in this control (presented in numerical order). This list provides an explanation of each data field, and will serve as a reference for all fields in the system.
  • Page 14 ZONE SOUNDS AND SINGLE ALARM SOUNDING PER ZONE Default is 0. TIMING (Per Armed Period) (1-Digit Entry) ( 28– 39) This field limits external alarm sounding to once per arming period for a given zone. Enter 1 for yes; 0 for no. For UL installations, enter 0 for unlimited Alarm Soundings FIRE SOUNDER TIMEOUT (1-Digit Entry)
  • Page 15 Determine which format is to be used to report to the central station. Enter 1 digit (0–9). For an explanation of these 0 = 3+1; 4+1 ADEMCO Lo Speed Standard (this is the default) formats, see the SYSTEM 1 = 3+1; 4+1 Radionics Standard...
  • Page 16 1234–911–004 Example 1. Pager displays: This indicates that Subscriber No. 1234’s system is reporting an Alarm (911), due to zone 4 being faulted (004). 1234–001–005 Example 2. Pager displays: This indicates that Subscriber No. 1234’s system is reporting an opening (001) by User 5 (005). Note that no restore reports are sent to the pager.
  • Page 17 A "0" (not "# + 10") in both boxes will disable the re port. With Ademco Contact ID Reporting: Enter any digit (other than "0") in the first box, to enable zone to report This is an "enabling" code only and is disregarded in the actual reporting to the central office.
  • Page 18 AWAY/STAY CLOSE REPORT CODE (2-Digit Entry) (See box on previous page.) To enable, enter a code (or 0 to disable) in either or both boxes. For expanded or 4+2 reporting, 2nd digit for each = User # . RF XMTR. LOW BATTERY REPORT CODE (2-Digit Entry) (See box on previous page).
  • Page 19 INITIALIZE DOWNLOAD ID AND SUBSCRIBER ACCT. No. FOR DOWNLOADING (No data entry required; press 96) SET ALL PROGRAM FIELDS TO DEFAULT VALUES (No data entry required; pressing 97 automatically loads all Ademco defaults). Do not use if previously programmed with other values. TO EXIT...
  • Page 20: Remote Programming And Control (Downloading)

    • Either a HAYES brand SMARTMODEM 1200 [Level 1.2 or higher external or Level 1.1 or higher (with 4 position DIP switch) internal style],or a HAYES brand Optima 24 Plus FAX96 Modem. • Ademco’s V-Link ® downloading software (Rev. 4 or higher) or Ademco’s Compass Windows downloading software. • Appropriate interconnecting cables.
  • Page 21: Remote Programming Advisory Notes

    The detailed operation of the download functions is covered in the instructions for Ademco’s V-Link ® downloading software (Rev. 4 or higher) or Ademco’s Compass Windows downloading software.. Remote Programming Advisory Notes •...
  • Page 22 – NOTES – – 22 –...
  • Page 23: Summary Of Connections Diagram

    USED, BUT USE MAX. OF 220 FT. OWNER'S INSTRUCTION NOTICE NOT TO BE REMOVED. WEEKLY TESTING IS TO A POLICE EMERGENCY NUMBER. OF #22 WIRE OR 550 FT. OF #18. REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM. ADT VISTA-10SE SUMMARY OF CONNECTIONS...
  • Page 24 165 Eileen Way, Syosset, New York 11791 Copyright © 1997 PITTWAY CORPORATION...

Table of Contents