VISTA-10SEa Installation and Setup Guide
02
STP – –
You can review previously entered data by pressing [#]80. After you choose the relay
number, press [ ] to go to the next screens.
This is a Review mode only, and data cannot be changed.
Example of Output Relay Programming
A lamp is to be turned on when any one of 3 specific zones is faulted or when any
24-hour auxiliary zone is disturbed. You want to turn off the lamp manually
without affecting the arming status of the system.
In field 80, you would choose Output Relay 01 and program the Action (A) to be "2" (Close
and Stay Closed). The Event you are looking for to start the relay action is a fault, so
program "2" in (EV). You will use Zone List 1 for the 3 specific zones, so program "1" in (ZL),
and program these 3 zones in field 81's Zone List 1. The second condition for turning on the
indicator is triggering a 24-hour aux. zone (Zone Type 08), so you will program (ZT) as "08."
To stop relay action and turn off the indicator, you do not want to use a restore of any zone,
so you will program a "0" for the "Restore of" Zone List (ZL). To choose a manual entry of
[User Code] + [#] + [7] to turn it off, program (ZT) as "34" (see "Choices for System Operation"
in the table above).
If no other relay is to be programmed, you would go to field *81 and program the three
specific zones in Zone List 1.
Press 81 (Zone Lists for Output Relays). This Interactive menu mode is applicable only if
you have programmed 80 mode.
Refer to the Programming Form worksheet for
separate Programming Guide.
Zone List Displays
Zone List No.
(00 = Quit)
01
(00 = Quit)
01 Del Zn List?
0 = No 1 = Yes
01 Delete Zone?
0 = No 1 = Yes
7-6
This screen again displays a summary of the current relay
A EV ZL ZT
STOP programming.
0
00
Press [ ] to continue.
The display then returns to the first screen so that the next
relay number to be programmed can be entered. To end relay
programming, enter 00.
When you key 81, this screen will appear. Enter the Zone
List Number 01, 02, or 03 to program (or 00 to end these
01
entries). Press the [ ] key to advance.
In the following displays, Zone List 01 has been selected for
programming.
Enter each zone number to add to the zone list by first
Enter Zn Num.
entering the zone number, then pressing [ ] (for example,
00
01 , 02 , 03 ).
After all zones desired are entered, press 00 to advance.
To delete the zone list, enter 1 (Yes). All zones in the zone list
will be deleted automatically and programming will return to
0
the first screen.
To save the zone list, enter 0 (No) to advance.
To delete a zone or zones in a zone list enter 1 (Yes) to
advance.