ADEMCO Vista-10SEa Installation And Setup Manual page 26

Vista-10sea
Hide thumbs Also See for Vista-10SEa:
Table of Contents

Advertisement

VISTA-10SEa Installation and Setup Guide
Typical summary display
Zn ZT – RC
03 03 – 3C
Program Alpha?
0 = No 1 = Yes
Enter Zn Num.
(00 = Quit)
Enter next zone number 
Programming Panic Keys
When programming zones, note the following:
The defaults for Panic key pairs or individual Panic keys are:
Zone 07. [ ] and [#], or B: zone type 06 (24 Hr Silent).
Zone 95. [1] and [ ], or A: zone type 00 (not used).
Zone 96. [3] and [#], or C: zone type 00 (not used).
Panic keys are programmed (or reprogrammed) by keying the zone number, e.g., 07, 95,
and 96, and entering the desired zone type that will provide the desired Panic function for
each of these keys, using the list of zone types below.
06 = 24-Hr Silent
07 = 24-Hr Audible
08 = 24-Hr Aux
09 = Fire
When you have programmed all the basic wired zones and Panic keys satisfactorily, exit 56
Interactive mode at the "Enter Zn Num." prompt by entering 00 as the next zone number.
Then exit the programming mode by keying 99.
See the special notes below, then proceed to the checkout procedure that follows.
Special Notes on Zone Programming
In field *56, at the summary line for each zone, you can check the entered values. If you
wish to change anything, press [#] to move to the previous entry. Press [#] a number of
times to move to earlier entries. Press [ ] to move to later entries again.
You can review zone entries by pressing [#]56. Changes cannot be made here, so this is
safer for review. Enter the first zone number to be viewed and press [#]. To view each
zone, press [#] and the zone number will advance to the next programmed zone. When
you reach the end of the list, press 00 to exit. You may also use this method of exiting at
any time during the review.
To remove a zone from the system either temporarily or permanently, go into
programming mode and press [ ] 56. Enter the zone number and press [ ]. At the "Zone
Type" prompt, enter 00 and [ ]. This sets the type of the zone to Not Used. The next
prompt will be "Delete Zone?". "Yes" will permanently remove the zone from the system,
while "No" will disable it but retain all data except the original zone type. You can then
go back to this zone later and put back an active zone type to re-enable it.
Checkout Procedure for Basic Wired Zones (1–6)
After you have completed installation and wiring of all devices/sensors on the basic wired
zones, you should check the system, as follows.
4-4
A summary display will appear, showing the data for the
In
L
zone that was just programmed.
HW: –
If it is programmed satisfactorily, press [ ] to continue.
The next request is to enter alpha descriptors for the
zones. You may make the entry now (enter 1), or at a later
0
time using 82 Interactive mode (enter 0). See Section 11:
ALPHA DESCRIPTOR PROGRAMMING for specific
procedure.
If you entered 0 (No) above, the system will return to the
"Enter Zn Num." prompt. Proceed with the programming
04
for the next zone, i.e., [ ] and zone number.