9-46 ELECTRICAL SYSTEM
SERVICING
Visually inspect the surface of the battery container. If any signs
of cracking or electrolyte leakage from the sides of the battery
have occurred, replace the battery with a new one. If the battery
terminals are found to be coated with rust or an acidic white
powdery substance, clean the battery terminals with sandpaper.

RECHARGING OPERATION

• Using the multi circuit tester, check the battery voltage. If the
voltage reading is the 12.0 V (DC) and less, recharge the bat-
tery with a battery charger.
• Remove the battery from the motorcycle.
Do not remove the caps on the battery top while
recharging.
Recharging time: 0.9 A for 5 to 10 hours or 4 A for 1 hour
Be careful not to permit the charging current to
exceed 5 A at any time.
• After recharging, wait for 30 minutes and more and check the
battery voltage with a multi circuit tester.
• If the battery voltage is the 12.5 V and less, recharge the bat-
tery again.
• If battery voltage is still 12.5 V and less, after recharging,
replace the battery with a new one.
• When the motorcycle is not used for a long period, check the
battery every 1 month to prevent the battery discharge.
A Charging period
B Stop charging
(V)
(at 0 – 40 ˚C)
14
13
12
11
10
100
75
50
25
Battety charged condition
0 (%)