MALFUNCTION CODE AND DEFECTIVE CONDITION

DETECTED
DTC No.
C00
NO FAULT
CKP sensor
C12
P0335
IAP sensor
C13/C17
H
P1750/
P0105
L
TP sensor
C14
H
P0120
L
ECT sensor
C15
H
P0115
L
IAT sensor
C21
H
P0110
L
DETECTED FAILURE CONDITION
ITEM
The signal does not reach ECM for 3
sec. or more, after receiving the starter
signal.
The sensor should produce following
voltage.
0.5 V
sensor voltage < 4.85 V
In other than the above range, C13
(P1750) (#2 cylinder) or C17 (P0105)
(#1 cylinder) is indicated.
Sensor voltage is higher than specified
value.
Sensor voltage is lower than specified
value.
The sensor should produce following
voltage.
0.2 V
sensor voltage < 4.8 V
In other than the above range, C14
(P0120) is indicated.
Sensor voltage is higher than specified
value.
Sensor voltage is lower than specified
value.
The sensor voltage should be the fol-
lowing.
0.15 V
sensor voltage < 4.85 V
In other than the above range, C15
(P0115) is indicated.
Sensor voltage is higher than specified
value.
Sensor voltage is lower than specified
value.
The sensor voltage should be the fol-
lowing.
0.15 V
sensor voltage < 4.85 V
In other than the above range, C21
(P0110) is indicated.
Sensor voltage is higher than specified
value.
Sensor voltage is lower than specified
value.
–––––––––––
FI SYSTEM DIAGNOSIS 4-27
CHECK FOR
–––––––––––
CKP sensor wiring and mechan-
ical parts
CKP sensor, lead wire/coupler
connection
IAP sensor, lead wire/coupler
connection
IAP sensor signal circuit shorted
to VCC or ground circuit open
IAP sensor signal circuit open or
shorted to ground or VCC circuit
open
TP sensor, lead wire/coupler
connection
TP sensor signal circuit shorted
to VCC or ground circuit open
TP sensor signal circuit open or
shorted to ground or VCC circuit
open
ECT sensor, lead wire/coupler
connection
ECT sensor circuit open or
ground circuit open
ECT sensor circuit shorted to
ground
IAT sensor, lead wire/coupler
connection
IAT sensor signal circuit open or
ground circuit open
IAT sensor signal circuit shorted
to ground

Hide quick links: