Servicing; Recharging Operation - Suzuki Intruder VZR1800 Service Manual

Hide thumbs Also See for Intruder VZR1800:
Table of Contents

Advertisement

SERVICING

Visually inspect the surface of the battery container. If any signs
of cracking or electrolyte leakage from the sides of the battery
have occurred, replace the battery with a new one. If the battery
terminals are found to be coated with rust or an acidic white
powdery substance, clean the battery terminals with sandpaper.

RECHARGING OPERATION

• Using the multi-circuit tester, check the battery voltage. If the
voltage reading is the 12.0 V (DC) and less, recharge the bat-
tery with a battery charger.
#
* When recharging the battery, remove the battery
from the motorcycle.
* Do not remove the caps on the battery top while
recharging.
Recharging time: 9 A for 1 hour or 1.8 A for 5 to 10 hours
#
Be careful not to permit the charging current to
exceed 9 A at any time.
• After recharging, wait for 30 minutes and more and check the
battery voltage with a multi-circuit tester.
• If the battery voltage is the 12.5 V and less, recharge the bat-
tery again.
• If battery voltage is still 12.5 V and less, after recharging,
replace the battery with a new one.
• When the motorcycle is not used for a long period, check the
battery every 1 month to prevent the battery discharge.
A Charging period
B Stop charging
ELECTRICAL SYSTEM
(V)
(at 0 – 40 ˚C)
14
13
12
11
10
100
75
50
25
Battety charged condition
10-45
0 (%)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vzr1800

Table of Contents