EN | 22

Setup using a terminal program

Data terminal
You can connect a data terminal to the VIP X for setup and local control. The
data terminal consists of a computer with terminal software. You can use the
supplied configuration cable to make the connection (for pin assignment of the
orange terminal block, see page 106).
HyperTerminal, a communications accessory included with Microsoft Windows,
can be used as the terminal program.
Note
Information on installing and using HyperTerminal can be found in the user
guides or online help for MS Windows.
– Before using the terminal program, disconnect the VIP X from the data
network and disconnect the power supply unit from the mains socket.
– Connect the open lines of the configuration cable with the terminal block that
is already connected to the power supply unit. The assignment can be seen
from the labels on the configuration cable and the markings on the terminal
block.
– Connect the terminal block with the orange socket on the unit.
– Connect the VIP X configuration cable with a free serial port on your
computer.
– Ensure that the correct primary adapter is fitted and connect the power supply
unit to an appropriate mains socket.
Configuring the terminal
To establish communication between the terminal program and the VIP X, the
transmission parameters must be correctly defined. The following values should
be set in the terminal program:
19,200 Bit/s
8 data bits
No parity check
1 stop bit
No protocol
Installation
Installation and Operating Manual | VIP X1/VIP X2
Bosch Security Systems | 2005-10 | V1.5