Dido Do Power Alarm; Dido Fault Act - Planet MGSD-10080F User Manual

10-port gigabit managed metro ethernet switch
Hide thumbs Also See for MGSD-10080F:
Table of Contents

Advertisement

DIDO DO Power Alarm

Description:
Set or show the system digital output0/1 power alarm.
Syntax:
DIDO Do_pwr_alr [first|second] [dc1|dc2] [enable|disable]
Parameters:
first
: Digital Input/Output 0
second : Digital Input/Output 1
(default: Set or show digital input/output first(0)/second(1) select)
dc1
: DC power 1
dc2
: DC power 2
(default: Set or show digital output/fault alarm 0/1 power_fail)
enable : Enable digital input0/1 function
disable : Disable digital input0/1 function
(default: Set or show digital input/output/fault alarm 0/1 status)

DIDO Fault Act

Description:
Set or show the system fault alarm action.
Syntax:
DIDO Fault_act [port|power] [enable|disable]
Parameters:
port
: port fail
power
: power fail
DI1
: DI1 trigger
DI2
: DI2 trigger
(default: Set or show digital output/fault alarm 0/1 action)
enable : Enable digital input0/1 function
disable : Disable digital input0/1 function
(default: Set or show digital input/output/fault alarm 0/1 status)
607
User's Manual of MGSD-10080F

Advertisement

Table of Contents
loading

Table of Contents