1-6-7 DF section
(1) Detaching and refitting the DF forwarding pulley and DF feed pulley (18 cpm copier only)
Follow the procedure below to clean or replace the DF forwarding pulley or DF feed pulley.
Procedure
1. Remove the two screws holding the DF lower
left cover and theb the cover.
2. Remove the stop ring, then remove the DF
original switchback cover.
• Detaching the DF forwarding pulley
3. Remove the two stop rings, then remove the
DF forwarding pulley assembly.
4. Remove the DF forwarding pulley, and clean
or check the pulley.
DF lower left cover
Figure 1-6-80
DF original switchback cover
Stop ring
Figure 1-6-81
Stop rings
DF forwarding pulley
Figure 1-6-82
2A1/2
1-6-45