(2) Detaching and refitting the scanner wires

Take the following procedure when the scanner wires are broken or to be replaced.

(2-1) Detaching the scanner wires

Procedure
1. Remove the right cover, left cover, rear cover,
upper front cover and contact glass.
2. Move the mirror 1 frame to the cutouts of the
machine.
3. Detach the inverter wire from the inverter
PCB.
4. Remove the screw holding each of the front
and rear wire retainers.
5. Remove the mirror 1 frame from the scanner
unit.
6. Unhook the round terminal of the scanner
wire from the scanner tension spring on the
right side of the scanner unit.
7. Remove the scanner wire.
Inverter wire
Figure 1-6-32
Wire retainer
Figure 1-6-33
Scanner tension springs
Figure 1-6-34