Taking the boiler out of operation

10 Taking the boiler out of operation

10.1 Normal boiler shut-down

With Buderus Logamatic control: Switch the ON/OFF
switch on the control panel OFF (position "0"). This
switches the boiler and all its components OFF (for
example the burner).
When using the aquastat: Shut off main heating
system switch (position "OFF"). This switches off the
boiler with all its components.
Further shut-down procedure
documentation.
Shut off fuel supply by closing main valve.
SYSTEM DAMAGE
due to freezing temperatures.
The heating system can freeze up in cold
CAUTION!
weather if it has been switched off.
Leave the heating system switched on
as long as possible.
Protect your heating system against
freezing by draining the heating
system and hot water pipes at the
lowest possible point.

10.2 Emergency shut-down

Explain to your customer the measures required in
emergencies, for example in case of fire:
Proceed as follows in an emergency, such as a fire:
Shut off fuel supply by closing main valve.
Isolate the heating system from the electrical power
supply via the heating system emergency stop switch
or the building circuit-breaker.
We reserve the right to make any changes due to technical modifications.
Installation and maintenance instructions Logano G215 US oil/gas-fired boilers • Issue 11/2004
refer to aquastat
Fig. 66 Shutting down the heating system (Logamatic 2000)
1 ON/OFF switch
Fig. 67 Heating system shut-down (with aquastat)