Taking the heating system out of operation

4
Taking the heating system out of operation
4.1

Normal system shut-down

1. Turn ON/OFF switch (emergency shutoff switch) to
OFF position. This shuts off power to the boiler and
all of its components (e.g. burner, aquastat).
2. Close gas shut off.
SYSTEM DAMAGE
due to freezing.
The heating system can freeze up in cold
CAUTION!
weather if it is shut down.
Leave the heating system switched ON
constantly as much as possible.
Protect the heating system from freezing
by draining the boiler and water pipes at
the lowest point.
4.2

Emergency shut-down procedures

Perform this procedure in case of emergency:
1. Never put yourself at risk. Your own safety must
always take priority.
2. Shut off main gas supply.
3. Shut down the heating system using the boiler
emergency shutoff switch or the corresponding
circuit-breaker.
We reserve the right to make any changes due to technical modifications.
User manual Gas Boiler Logano GC124 II/SP • Issue 07/2006
1
Fig. 10 System shut-down
1 ON/OFF switch (emergency shut off switch)