Interlogix TruVision DVR 20 User Manual page 78

Truvision dvr 20
Table of Contents

Advertisement

53BChapter 6: Advanced setup
Figure 37: Alarm and event setup screen
To set up how to respond to an alarm or event:
1. In the Menu toolbar click the Alarm icon.
2. Click the Setup submenu. The Alarm & Event Setup screen appears.
3. Change the settings, as required:
Option
Alarm Input
Alarm Mode
Input Type
Buzzer on Alarm
Buzzer on Video Loss
74
Description
Select the external alarm input.
Set the output mode for when the alarm is triggered. There are
three types to choose form:
Timeout: The alarm condition is latched for the amount of time
specified in the timeout field displayed alongside. The timeout
can be up to a maximum of 99 seconds.
Transparent: The alarm is active only while receiving alarm input.
Latched: The alarm is activated until it is manually acknowledged.
See "Manually acknowledging an alarm" on page 60 for further
information.
Caution: An alarm can only be acknowledged locally. Do not
select the latched option if the TVR 20 is controlled over a
network.
Depending on the sensor type, select either NO or NC. Default is
NO.
Check to have an audible alarm when an alarm is triggered.
Video may be lost if the video cable or camera develop a fault.
Check to have an audible alarm when the video image is lost.
TruVision DVR 20 User Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents