Machine Parameter 000 ~ 006 — Factory use only
Machine Parameter 007
Switch
Initial
Setting
7
0
Factory use only
6
0
Factory use only
5
0
Factory use only
4
0
DRAM capacity indication
on the Main PCB
3
0
2
0
1
0
0
0
DRAM capacity indication
on the Main PCB
Machine Parameter 008 and 009 — Factory use only
Machine Parameter 010
Switch
Initial
Setting
7
0
ADF scanner registration
adjustment (Horizontal)
6
0
5
0
Adjusts the start point to
4
0
scan the document.
3
0
The plus setting increases
2
0
the left margin and the minus
1
0
setting decreases it.
0
0
1 step = 2 / 600 dpi
Note: These values
are factory set and should
not be adjusted unless
instructed by a Muratec
technical representative.
Adjust
Adjust
(0.0847 mm)
3-5
Usage/Comments
This switch indicates the DRAM capacity.
(This switch is read only, do not set any character)
You can see the memory capacity by how many "1"
is indicated on the LCD. One "1" means 8MB.
For example, if three "1" are indicated,
i.e. "00000111", the DRAM capacity is
8MB x 3 = 24MB.
Usage/Comments
Switch
76543210
127 steps 01111111
:
00100000
:
00010000
:
00001000
:
00000000
:
10001000
:
10010000
:
10100000
:
-127steps 11111111
Settings
+10.76 mm
+2.71 mm
+1.36 mm
+0.68mm
0 mm Initial setting
-0.68 mm
-1.36 mm
-2.71 mm
-10.76 mm