Attribute 3 - Individual Autodialer Setting
Initial
Switch
Setting
7
0
Factory use only
6
0
Factory use only
5
0
Changing the date format of
the transmitted TTI
0: No
1: Yes
4
1
TTI transmit
0: No
1: Yes
(Note: Turning TTI
transmission off may violate
local or federal regulations.)
3
0
ECM response time
0: 3 sec
1: 4.8 sec
2
0
ECM error retransmit time
0: 200 ms
1: 400 ms
1
0
Interval between DIS and DCS
0
0
Switch 1
Switch 0
Adjust
When set to "1", the machine changes the date
format of the transmitted TTI from MM: DD: YY, or
vice versa.
When set at "0", transmission of the TTI is disabled.
The TTI includes the followings:
• Sender name
• Sender's fax number
• Data & time, and number of pages
To set the individually transmission of them, see
Memory SW 016.
The time limit to receive the response signal for the
ECM post message.
The time limit before the ECM error is retransmitted.
0 ms 500 ms 1000 ms 1500 ms
0
0
1
0
1
0
3-76
(Equivalent to Memory Switch 012)
Usage/Comments