Muratec MFX-2050 Field Engineering Manual page 141

Facsimile system
Hide thumbs Also See for MFX-2050:
Table of Contents

Advertisement

Memory Switch 012 — Transmission
Initial
Switch
Setting
7
0
6
0
5
0
 
4
1
3
0
 
 
2
0
 
1
0
 
0
0
Memory Switch 013 — Transmission
Initial
Switch
Setting
7
0
 
6
0
 
5
0
 
4
0
 
3
0
 
2
1
1
0
0
0
Adjust
Factory use only
Factory use only
Changing the date format of
the transmitted TTI
0: No
1: Yes
TTI transmit
0: No
1: Yes
(Note: Turning TTI
transmission off may violate
local or federal regulations.)
ECM response time
0: 3 sec
1: 4.8 sec
ECM error retransmit time
0: 200 ms
1: 400 ms
Interval between DIS and DCS
0 ms 500 ms 1000 ms 1500 ms
Switch 1
0
0
Switch 0
0
1
Adjust
ANSam detection
0: Yes
1: No
V.34 transmission
0: Yes
1: No
CSI/TSI/CIG transmit
0: Yes
1: No
ECM mode
0: On
1: Off
Retransmit automatically
when receiving RTN/PIN
signals
0: Yes
1: No
Factory use only
Factory use only
Factory use only
Usage/Comments
When set to "1", the machine changes the date
format of the transmitted TTI from MM:DD:YY, or
vice versa.
When set at "0", transmission of the TTI is disabled.
The TTI includes the followings:
• Sender name
• Sender's fax number
• Data & time, and number of pages
To set the individually transmission of them, see
Memory SW 016.
The time limit to receive the response signal for the
ECM post message.
The time limit before the ECM error is retransmitted.
1
1
0
1
Usage/Comments
During the V8 handshake, if some noise disturbs
the handshake and an error occurs, set to "1".
Individual setting for V.34 transmission.
When set at "1", transmission of the CSI, TSI and
CIG signals are disabled.
Determines ECM mode. ECM mode reduces
document memory and may lengthen transmission
and reception times.
When set to "1", retransmission disables
automatically if receiving RTN/PIN signals.
3-57

Advertisement

Table of Contents
loading

This manual is also suitable for: