Muratec MFX-2050 Field Engineering Manual page 181

Facsimile system
Hide thumbs Also See for MFX-2050:
Table of Contents

Advertisement

Unique Switch 070 — Operation
Initial
Switch
Setting
7
0
Factory use only
6
1
LCD error message
0: Remains in LCD
1: Returns to standby
5
1
Factory use only
4
0
Factory use only
3
0
Factory use only
2
0
Factory use only
1
0
Factory use only
0
0
Factory use only
Unique Switch 071 — Operation
Initial
Switch
Setting
7
1
Line monitor in Quick memory
transmission
0: Off
1: On
6
0
Factory use only
5
1
Factory use only
4
0
Factory use only
3
0
Factory use only
2
0
Factory use only
1
0
Rx document to polling
document
0: No
1: Yes
0
0
Factory use only
Adjust
After an error message has printed, the setting of
this switch determines if the error message will
remain in the display.
Adjust
Retrieve the document received in the memory by
polling transmission.
3-97