Memory Switch 070 — Operation
Initial
Switch
Setting
7
0
Display error line
0: No
1: Yes
6
0
Tonal line monitor
0: No
1: Yes
5
0
Factory use only
4
0
Sort autodialer printout
0: Sort by autodialer location
1: Sort by location ID
3
1
Print check message if power
is lost
0: No
1: Yes
2
1
Print page if error occurs
during memory transmission
0: No
1: Yes
1
1
Print check message
0: No
1: Yes
0
0
Factory use only
Adjust
The number of error lines contained in the received
data will be shown in the LCD.
Allows fax communication to be heard through the
monitor speaker.
Specifies how entries on autodialer printouts are
sorted.
In the event of two power losses in a 40-hour
period, documents will be lost. When power is
restored, a check message will print.
For easy identification, the first page of a document
stored for memory transmission will print along a
check message if an error occurs during memory
transmission.
To notify the user of an error, a check message can
be printed if a communication error occurs.
3-69