Muratec MFX-2050 Field Engineering Manual page 171

Facsimile system
Hide thumbs Also See for MFX-2050:
Table of Contents

Advertisement

Unique Switch 030 — Modem
Initial
Switch
Setting
7
0
6
0
5
1
 
4
1
 
3
1
 
 
2
1
1
0
0
1
 
Unique Switch 031 — Modem
Initial
Switch
Setting
7
0
 
6
0
5
0
4
1
3
0
2
1
1
0
0
0
Adjust
Factory use only
Factory use only
3429 baud symbol rate when
communicating at V.34
0: No
1: Yes
3200 baud symbol rate when
communicating at V.34
0: No
1: Yes
3000 baud symbol rate when
communicating at V.34
0: No
1: Yes
2800 baud symbol rate when
communicating at V.34
0: No
1: Yes
Factory use only
2400 baud symbol rate when
communicating at V.34
0: No
1: Yes
Adjust
Forced 2400 symbol rate
when probing SNR is adverse
Usage/Comments
If the error frame often occurs because of the
symbol rate is too high, setting this switch to
"1" mask that symbol rate and keep down the
occurrence of error frame.
See above (switch 5 to 2).
Usage/Comments
SNR means that Signal Noise Ratio.
If the SNR is less than the threshold you set,
the modem overrides the bandwidth evaluation
algorithm and forces the symbol rate to2400 baud.
3-87