Memory Switch 000 — Dialer
Initial
Switch
Setting
7
0
6
0
5
0
 
4
0
3
0
 
2
1
 
1
1
 
0
0
 
Adjust
Factory use only
Factory use only
CED detection condition
DIS detect time after dialing
0: 55 sec
1: 70 sec
CED detection
0: No
1: Yes
Dial tone detection
0: Do not dial
1: Dial
Phone line type for the first
phone line
0: PSTN
1: PBX
Usage/Comments
Sets whether the detection should be strict or not.
Normal 
350ms 500ms 700ms 1000ms
Switch
5
0
4
0
Sets the time DIS signal is detected after dialing a
number.
Can be use to ignore CED detection if noise on
the telephone line is mistaken as a 2100 Hz CED
signal.
Determines if the machine proceeds with dialing or
indicates an error if no dial tone is detected within
five seconds of going off-hook.
When set to PSTN, the machine checks for dial
tone and acts according to the setting of memory
switch 000, bit 1. When set to PBX, the machine
always dials a given number of seconds after going
off-hook. Memory switch 001 sets the number of
seconds.
3-51
Strict
0
1
1
1
0
1