Muratec MFX-2050 Field Engineering Manual page 138

Facsimile system
Hide thumbs Also See for MFX-2050:
Table of Contents

Advertisement

Memory Switch 005 — Dialer
Initial
Switch
Setting
7
0
6
1
 
5
1
4
0
3
0
 
2
0
 
1
0
 
0
1
 
Memory Switch 006 ~ 009 — Factory use only
Adjust
Factory use only
Ring signal detect time
Number of CI signal detection
in Fax/Tel Ready mode
0: Detect 1 time
1: Detect 2 times
Dual ring detection
0: No
1: Yes
Long ring detection
0: No
1: Yes
Frequency of the CI signal
detection
0: No
1: Yes
Usage/Comments
Set the time that an incoming ring will not be detected
after hanging up. (Fax/Tel Ready mode only.)
Switch 6 5 4
0 0 0
100 ms
0 0 1
200 ms
0 1 0
300 ms
0 1 1
400 ms
1 0 0
500 ms
1 0 1
600 ms
1 1 0
700 ms
1 1 1
800 ms
Select the number of detection time of CI signal in
the Fax/Tel Ready mode or in the ringer silent mode.
Incoming calls are answered according to this setting
regardless of the number of rings chosen in the User
Settings.
When enabled, the machine is able to auto answer
an incoming ring with an off time of 120 - 60 ms.
Allows the machine to respond to an incoming ring
if the ring on time is longer than two seconds.
When disabled, the unit will not check the frequency of
the incoming CI signal.
3-54