A Drive Power On Reset Detected; B Rebuild Paused - 3Ware 9650SE-2LPML User Manual

Serial ata raid controller
Hide thumbs Also See for 9650SE-2LPML:
Table of Contents

Advertisement

003A Drive power on reset detected

003B Rebuild paused

www.3ware.com
Action
None required.
If errors persist, contact technical support at
index.asp.
Event Type
Error
Cause
The controller has detected that a drive has lost power and then restarted. The
controller may degrade the unit if it is a redundant unit (non-redundant units
cannot be degraded).
Action
If this drive was the only one to lose power, check the cable connections.
Also, check that your power supply is adequate for the type and number of
devices attached to it.
See Also
For troubleshooting information and a link to drive manufacturer diagnostic
utilities, see
http://www.3ware.com/KB/article.aspx?id=14927.
Event Type
Information
Cause
The rebuild operation is paused.
Rebuilds are normally paused for two (formerly ten) minutes after a system
first boots up and during non-scheduled times when scheduling is enabled.
Disabling or modifying the schedule with 3DM or CLI will allow the rebuild
to resume.
See Also
"Scheduling Background Tasks" on page 156
Error and Notification Messages
http://www.3ware.com/support/
249