Migration Completed; Verify Fixed Data/Parity Mismatch; So-Dimm Not Compatible - 3Ware 9650SE-2LPML User Manual

Serial ata raid controller
Hide thumbs Also See for 9650SE-2LPML:
Table of Contents

Advertisement

0035 Migration completed

0036 Verify fixed data/parity mismatch

0037 SO-DIMM not compatible

www.3ware.com
Event Type
Information
Cause
The migrated unit is now ready to be used.
Migration changes can include:
Expanding capacity of a unit by adding drives
Changing RAID levels, for example, from RAID 1 to RAID 5.
Action
If the capacity of the unit did not change, then you do not need to do anything
else. If the capacity of the migrated unit is larger, you will need to inform the
operating system of the change. See "Informing the Operating System of
Changed Configuration" on page 119.
Event Type
Warning
Cause
A verify error was found and fixed by the 3ware RAID controller.
Some examples of errors that can be fixed include:
A parity inconsistency for a RAID 5 or RAID 50 unit.
A data mismatch for a RAID 1 or RAID 10 unit.
Action
None required.
Event Type
Error
Cause
There is incompatible SO-DIMM memory connected to the 9500S controller.
Error and Notification Messages
247