Battery Voltage Is Too High; Battery Temperature Is Normal - 3Ware 9650SE-2LPML User Manual

Serial ata raid controller
Hide thumbs Also See for 9650SE-2LPML:
Table of Contents

Advertisement

0048 Battery voltage is too high

0049 Battery temperature is normal

www.3ware.com
Event Type
Error
Cause
The battery pack voltage being monitored by the Battery Backup Unit is too
high to backup the 3ware RAID controller.
Action
The battery pack must be replaced.
This may be a fault in the BBU control module. If you get this error, do the
following:
1
Turn off the computer and remove the 3ware RAID controller.
2
Remove the BBU control module and battery module from the 3ware
RAID controller.
3
Unplug the battery from the control module.
4
Return the BBU control module and battery module to 3ware.
For more details on removing the BBU, see the installation guide that came
with your 3ware RAID controller.
Event Type
Information
Cause
The battery pack temperature being monitored by the Battery Backup Unit
fell outside of the acceptable range and then came back within the acceptable
range.
Action
None required
Error and Notification Messages
255

Advertisement

Table of Contents
loading