3Ware 9650SE-2LPML User Manual page 123

Serial ata raid controller
Hide thumbs Also See for 9650SE-2LPML:
Table of Contents

Advertisement

Table 9: StorSave Profile Definitions
Definition
FUA (Force Unit
Access)
Write Journaling
Disable Cache on
Degrade
www.3ware.com
Protection (Default)
Maximum data
protection, but slower
performance.
Honor FUA (If no BBU is
present)
Ignore FUA (If BBU is
present)
Enabled
Enabled
FUA (Force Unit Access)
controller or a program (such as a database program) can ensure that data
is actually written to the disk drive media, and is not stored in cache.
When a write command is followed with a FUA command, then the disk
drive will only issue "command complete" to the controller once the data
is written to media. When performance is considered more important than
protection, it may be desirable to ignore FUA commands.
The Protection and Balanced profiles honor FUA commands if no BBU is
present; the Performance profile ignores them regardless of whether a
BBU is present.
If you use a battery backup unit (BBU), FUA is ignored, because the BBU
preserves the contents of the controller cache memory for a limited period
of time (up to 72 hours), in the event of a power failure.
Write Journaling
. Write journaling tracks the writing of data to disk and
preserves a copy of data that has not yet been written to the disk media.
Following a power failure or in the event of accidental drive removal and
reinsertion, the firmware can recover the unit without data loss. All
pending writes sitting in the controller cache are replayed after power is
restored or the drive is reinserted and are flushed from the controller to
the drive.
Using write journaling helps protect your data, however it can have an
impact on performance.
Balanced
More data protection than
Performance but less
data protection than
Protection.
Honor FUA (If no BBU is
present)
Ignore FUA (If BBU is
present)
Disabled, if no BBU
present. (Enabled, if BBU
is present.)
Disabled
. FUA commands are a way that the RAID
Setting Unit Policies
Performance
Maximum performance
for the unit, but less data
protection.
Ignore FUA
Disabled (If BBU is
present, this essentially
disables the BBU for this
unit.)
Disabled
113