Omron SYSMAC C200H-IDS01-V1 Operation Manual page 86

Id sensor
Hide thumbs Also See for SYSMAC C200H-IDS01-V1:
Table of Contents

Advertisement

Timing Considerations
C200H-IDS01-V1
Data Carrier
IDS
mode
V600-D@@R@@
---
(battery builtin
type)
V600-D@@P@@
Commu-
(with no battery)
nica-
tions
dis-
tance
priority
mode
Commu-
nica-
tions
speed
priority
mode
C200HIDS21
Command
Read/Write command (including auto command)
Clear all command
Data Carrier Moving
Speed
Refer to the following tables for the processing time of each command used
for communications between the ID Sensor Unit and Data Carrier.
Command
1
Read
54
59
Write (clear
96
109 127 162 232 374 709
all)
Read
72
86
Write
185 212 249 322 468 760 1345 2515 ---
Read
85
91
Write
197 219 250 309 428 667 1145 2098 ---
Note
1. The IDS mode is set with pin 2 of the DIP switch.
2. The time required for command processing of the Data Carrier with a built-
in battery is not influenced by the IDS mode.
3. 3.2k and 8k bytes only allow the execution of the clear all command.
Use the following formula to obtain the moving speed of the Data Carrier.
Moving speed =
Refer to the above tables for the processing time of each command. The Data
Carrier's moving distance in the communications zone varies with the combi-
nation of the R/W Head and Data Carrier. Refer to the appropriate R/W Head
and Data Carrier Operation Manual.
Data Carrier
4
8
16
32
64
66
82
111 172 293
104 141 213 357 646
99
113 144 205 326
1
4
8
16
90
95
105 120 200 355 665 1285 2530 5015 ---
---
---
---
---
Moving distance in the communications zone
Command processing time
d
d: Moving distance within communications zone
R/W Head
Byte
128
256
512
536
1000 1986 ---
1220 2349 4607 9123 36128
1224 ---
---
---
567
---
---
---
Byte
32
64
128
256
---
---
---
---
Communications zone
Section 3-3
1K
2K
8K
---
---
---
---
---
---
---
---
---
512
1K
2K
---
---
9875
71

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysmac c200h-ids21