Omron SYSMAC C200H-IDS01-V1 Operation Manual page 75

Id sensor
Hide thumbs Also See for SYSMAC C200H-IDS01-V1:
Table of Contents

Advertisement

Monitoring
Setting Addresses
Setting Addresses (Direct Input)
ADRS
1
F
Setting Addresses (INC/DEC keys)
INC
DEC
60
First select either a start address (STadrs) or end address (EDadrs) as
described under the previous heading Selecting Start and End Addresses.
Then enter the desired value for the start address or end address. The values
can be input either directly or by using the INC/DEC keys. Refer to the follow-
ing figures.
HEAD 1 PAGE 1
STadrs_ data 00
HEAD 1 PAGE 1
STadrs1 data 00
HEAD 1 PAGE 1
STadrs1F data 00
The address can also be input or changed using the INC or DEC keys, as
shown below.
HEAD 1 PAGE 1
STadrs20 data 00
HEAD 1 PAGE 1
STadrs1F data 00
When setting the address, be sure that the end address is equal to or greater
than the start address. If a value input for the end address is less than that of
the start address, the buzzer will sound and the input will not be accepted.
When the last value is input, the entire address is automatically set; it is not
necessary to press the SET key.
Change the current address (start or
end address) by first pressing the
ADRS key and then entering the
desired value. In this example, the
start address is changed to 1F.
Enter the value (from 0 through F) of
the leftmost digit of the address. In
this example, the higher digit is 1.
Enter the value (from 0 through F) of
the rightmost digit of the address. In
this example, the lower digit is F.
The address is incremented each time
the INC key is pressed. Note that the
address is set in hexadecimal.
The address is decremented each time
the DEC key is pressed.
Section 3-2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysmac c200h-ids21

Table of Contents