Monitoring
Statistical Error Information (Key 2)
ERR
2
INC
"S" =
"Statistical"
INC
INC
Mean Cycle Be-
tween Failures
DEC
ERROR1 2 3 4
L S CL CS
STA.ERRORS INF.
90-09-05
Year Month Day
STA.ERRORS INF.
S 9 1 COM.DC E
Error message
Number of
times an er-
R/W Head word
ror occurred
number (fixed to 1)
or
STA.ERRORS INF.
S 9 1 error70
Error code number
STA.ERRORS INF.
S152 1 PROTCT E
STA.ERRORS INF.
MCBF S 1357
MCBF (1 through
9999999)
"S" = "statistical"
STA.ERRORS INF.
S152 1 PROTCT E
(Continued on next page.)
Press key 2 to display the statistical
error information.
The date is displayed first. This date
was previously registered by the
user as the date from which errors
were to be monitored.
Press the INC key to display the
number of times an error has oc-
curred, the error message, and the
R/W Head word number.
Up to 999 errors can be displayed.
If 1000 errors have occurred, the
1000th error is displayed as 999.
Press the left or right arrow key to
alternately display the error code
number and error message.
If an error code is being displayed,
as in the example shown at left,
press the INC key again to display
the error message for the same er-
ror. Press the INC key once more
to display the next error code and
message.
After all messages have been dis-
played, press the INC key to dis-
play the MCBF. The MCBF value is
calculated using the following ex-
pression:
Total number
of commands
MCBF value =
Total number
of errors
(The MCBF is rounded off.)
If the MCBF value is 9999999 or
more, "9999999" will be displayed.
Press the DEC key to display the
previous screen.
Section 3-2