System Connections
Connecting the ID System
Connecting the Handheld
Programming Console
The Next Step
8
The information in this table applies only when no other Special I/O Units are
mounted to other Racks (PC or Expansion I/O Racks) and the Units in this
table are mounted only to a Remote I/O Slave Rack.
A
High-speed
High-density I/O
Counter, Position
Units, Temperature
Control Unit
Control Units, Cam
(NC111/NC112),
Positioner Unit
ASCII Unit, Analog
I/O Unit, ID Sensor
Unit, Fuzzy Logic
Unit
4 Units max.
---
---
8 Units max.
---
---
---
---
When combining Units from groups A, B, C, and D, use the following formulae:
3A + B + 2C + 6D ≤ 12
A + B + C + D ≤ 8
A maximum of ten Units can be mounted to one Remote I/O Slave Rack.
However, when mounting ten Units, the NC211 Position Control Unit is
counted as two Units and, if a PC Link Unit is used, it is counted as one Unit.
Refer to page 2 for an illustration of system connections.
Before connecting and wiring the ID Sensor Unit, turn OFF the power to the
PC.
Connect the R/W Head or Antenna to the ID Sensor Unit connector marked
"HEAD" or "Antenna". (To disconnect the cable, pull while grasping the outer
ring of the cable; do not pull at an angle.)
Refer to 3-2 Monitoring for information on connecting the Handheld Program-
ming Console.
Once you have completed installation of the ID Sensor system, turn to SEC-
TION 2 Operation for details on setup and operation.
B
C
Temperature
Sensor Unit, Voice
Unit
---
---
6 Units max.
---
Section 1-5
D
Position Control
Unit (NC211)
---
---
---
2 Units max.