Omron SYSMAC C200H-IDS01-V1 Operation Manual page 29

Id sensor
Hide thumbs Also See for SYSMAC C200H-IDS01-V1:
Table of Contents

Advertisement

Word Settings
IR Bit Allocation
Word
Bit number
n
00
01
02 through 15
n+1
00 through 11
(see note 2)
12 through 15
n+2
00 through 11
(see note 2)
12 through 15
n+3
00 through 11
(see note 2)
12 through 15
14
Bit name
Command
execution flag
Error reset flag
No. of command
data words
Command data
storage area
beginning word
number
Command data
storage area
Read data receiving
area beginning word
number
Read data receiving
area
Note
1. Only 512 words of data can be read or written, 4 words are used for com-
mand data.
2. At the leading edge of a command signal, the data of word n+1 through
word n+3 is valid.
3. The unused bits are provided for expansion. Do not use as work bits.
At the leading edge of the signal, the ID Sensor Unit reads
and executes the command.
While the ID Sensor Unit is waiting for a command, the error
reset flag is turned ON and the error flags in word n+4, bits 08
through 15 are turned OFF.
Not used (see note 3).
Indicates, in Binary Coded Decimal (BCD), the number of
words in the command to be executed. The maximum number
of words is 516 (see note 1).
Not used (see note 3).
Indicates, in BCD, the beginning word of the command to be
executed (stored in the CPU).
When the DM area exceeds DM 1000, turn ON bit 12.
Indicates the area where the command to be executed is
stored.
Bit number
15
14
13
12
***
0
0
0
0
0
1
0
0
1
0
0
0
1
1
0
1
0
0
0
1
0
1
0
***When the DM area exceeds DM 1000, turn ON bit 12.
The CPU reads the data from the Data Carrier using Read or
Auto Read. Specifies the beginning word of the area (in the
CPU) where the data is stored. The data is ignored when
Write, Auto Write, Clear-all, or Auto Read/Write Abort is
executed.
Specifies the area in the CPU in which the data read from the
Data Carrier (using Read or Auto Read) is stored. Refer to
word n+2, bits 12 through 15, to determine data areas. The
data is ignored when Write, Auto Write, Clear-all or Auto Read
or Auto Read/Write Abort is executed.
Section 2-2
Function
Area name
DM area
IR area
HR area
AR area
LR area
TIM/CNT