System Configuration

Back Panel C200H-IDS01-V1/IDS21
1-4

System Configuration

6
Backplane connector
Pin
No.
1
Screen messages
2
Local communications
mode (see note)
3, 4
Always OFF
Note The user can select the communications distance priority mode or
communications speed priority mode with pin 2 of the DIP switch
when the C200H-IDS01-V1 accesses the EEPROM Data Carrier.
Neither of these modes are, however, available when the ID Sensor
Unit accesses the SRAM Data Carrier or when the C200H-IDS21 ac-
cesses any Data Carrier, in which case turn pin 2 OFF. Refer to the
V600 FA ID System R/W Heads and EEPROM Data Carriers Oper-
ation Manual for the communications distance and speed of the EE-
PROM Data Carrier.
The diagrams below illustrate the system configurations of the C200H-IDS01-
V1 Electromagnetic Induction ID Sensor Unit and the C200H-IDS21 Micro-
wave ID Sensor Unit.
The ID Sensor Unit transfers data through the Read/Write Head (or Antenna)
to a Data Carrier, which is mounted on a moving workpiece. The ID Sensor
Unit transfers the desired data according to instructions from the user pro-
gram in the CPU (refer to 2-3 The User Program). Only one Read/Write Head
(or Antenna) can be connected to the ID Sensor Unit.
Data and error information can be monitored through a Handheld Program-
ming Console connected to the ID Sensor Unit. The data is displayed on the
screen of the Programming Console.
DIP switch
Function
OFF
Japanese
ON
English
OFF
Communications distance priority
mode
ON
Communications speed priority mode
Section 1-4