Omron SYSMAC C200H-IDS01-V1 Operation Manual page 83

Id sensor
Hide thumbs Also See for SYSMAC C200H-IDS01-V1:
Table of Contents

Advertisement

Monitoring
Newest Error Information (Key 1)
ERR
1
Indicates
how recent
the error is.
01: newest
30: oldest
INC
INC
DEC
If no error
occurred
RESET
68
ERROR1 2 3 4
L S CL CS
LAT.ERRORS INF.
N01 RD1 COM.DC E
Error message
Read/Write Head
word number
(fixed to 1)
Command that
caused the error
RD: Read
WT: Write
AR: Auto Read
AW: Auto Write
CA: Clear All
or
LAT.ERRORS INF.
N01 RD1 error70
Error code number
LAT.ERRORS INF.
N02 WT1 PROTCT E
LAT.ERRORS INF.
N30 AW1 VERIFY E
LAT.ERRORS INF.
N29 RD1 NO DC E
LAT.ERRORS INF.
NO ERROR
HEAD 1 PAGE 1
STadrs1F data 29
Press key 1 to display the command
that caused the error and the corre-
sponding error message.
Up to 30 errors can be displayed
sequentially by using the INC key.
Press either the left or right arrow
key to alternately display the error
code number and error message.
Each time the INC key is pressed,
the previous error is displayed.
If an error code is being displayed,
press INC to display the error mes-
sage associated with that code.
Each time the DEC key is pressed,
new errors are displayed in the
order in which they occurred.
If no errors have occurred, "NO
ERROR" is displayed.
To start another operation or abort
the operation, press the RESET
key and the display will return to
reset status.
Section 3-2