Omron SYSMAC C200H-IDS01-V1 Operation Manual page 39

Id sensor
Hide thumbs Also See for SYSMAC C200H-IDS01-V1:
Table of Contents

Advertisement

The User Program
Auto Read/Write Abort
Data Management
(IDS01-V1 Only)
Data Check
Usage
Command
24
This command aborts Auto Read and Auto Write. When this command is exe-
cuted, the ID Sensor Unit is initialized and waits for the next command.
15
A
A
4
1
4
*
2
A
0
If, after initialization, the ID Sensor Unit receives Auto Read/ Write Abort from
the CPU, the Unit recognizes it as an undefined command and waits for fur-
ther command input from the CPU. While the Unit is waiting for a command,
Waiting for Data Carrier (word n+4 bit 01) is ON.
By adding a check code to the Data Carrier data, it is possible to detect a data
error due to the battery of the SRAM Data Carrier or excessive overwriting
operations of the EEPROM Data Carrier. Use the MD-K command to calcu-
late and write the check code to the Data Carrier. Use the MD-C command to
collate the check code.
After data is written to the Data Carrier, use the MD-K command to calculate
and add the check code to the data. To check whether or not the Data Car-
rier's data is corrupted, use the MD-C command before reading the data and
collate the check code.
Write
stage
Read
stage
It is possible to calculate, write, or collate the CRC code (see note) in the
check area designated by the command. The CRC code is calculated by
using the generating function X
Note CRC stands for cyclic redundancy check. The cyclic redundancy
check is an error detection method.
00
This is OP (operation) code indicating
that the command is Auto Read/Write
Abort.
1
This is OP code represented in ASCII code.
Terminator
ASCII code
D
Data right
Check code calculation
Check code collation
Data read
16
12
+ X
+ X
Section 2-3
5
+ 1.