Download Print this page

Omron E2E Datasheet

Oil resistant cylindrical proximity sensor (automotive)
Hide thumbs Also See for E2E:

Advertisement

Quick Links

Oil resistant Cylindrical Proximity Sensor (Automotive)
E2E
Designed and tested for
Automotive assembly lines
• tested oil resistance on commonly used lubricants in
Automotive industry
Ordering Information
DC 2-wire/Pre-wired Models - enhanced oil resistant PUR/PE cable
Self-diagnostic
output function
No
Shielded
DC 2-wire/Pigtail-connector - enhanced oil resistant PUR/PE cable
Self-diagnostic
output function
No
Shielded
DC 2-wire/Pre-wired Models - PVC cable
Self-diagnostic
output function
Yes
Shielded
Unshielded
No
Shielded
Unshielded
*1. In addition to the above models, E2E-X@@15 models (e.g., E2E-X3D15-N), which are different in frequency from the above models, are available.
*2. E2E models with a robotics cable are available as well. The model number of a model with a robotics cable has the suffix "-R"
(e.g., E2E-X3D1-R).
*3. Cables with a length of 5 m are also available. Specify the cable length at the end of the model number (e.g., E2E-X3D1-N 5M).
E2E
Size
Sensing distance
M8
2 mm
M12
3 mm
M18
7 mm
M30
10 mm
Size
Sensing distance
M8
2 mm
M12
3 mm
M18
7 mm
M30
10 mm
Size
Sensing distance
M12
3 mm
M18
7 mm
M30
10 mm
M12
8 mm
M18
14 mm
M30
20 mm
M8
2 mm
M12
3 mm
M18
7 mm
M30
10 mm
M8
4 mm
M12
8 mm
M18
14 mm
M30
20 mm
NO
E2E-X2D1-U
E2E-X3D1-U
E2E-X7D1-U
E2E-X10D1-U
NO
E2E-X2D1-M1TGJ-U 0.3 M
E2E-X3D1-M1TGJ-U 0.3 M
E2E-X7D1-M1TGJ-U 0.3 M
E2E-X10D1-M1TGJ-U 0.3 M
NO
E2E-X3D1S (See note 1.)
E2E-X7D1S (See note 1.)
E2E-X10D1S (See note 1.)
E2E-X8MD1S (See note 1.)
E2E-X14MD1S (See note 1.)
E2E-X20MD1S (See note 1.)
E2E-X2D1-N (See notes 2 and 3.)
E2E-X3D1-N (See notes 1, 2 and 3.)
E2E-X7D1-N (See notes 1, 2 and 3.)
E2E-X10D1-N (See notes 1, 2 and 3.) E2E-X10D2-N
E2E-X4MD1 (See notes 2 and 3.)
E2E-X8MD1 (See notes 1, 2 and 3.)
E2E-X14MD1 (See notes 1, 2 and 3.) E2E-X14MD2
E2E-X20MD1 (See notes 1, 2 and 3.
Model
NC
E2E-X2D2-U
E2E-X3D2-U
E2E-X7D2-U
E2E-X10D2-U
Model
NC
E2E-X2D2-M1TGJ-U 0.3 M
E2E-X3D2-M1TGJ-U 0.3 M
E2E-X7D2-M1TGJ-U 0.3 M
E2E-X10D2-M1TGJ-U 0.3 M
Model
NC
---
---
---
---
---
---
E2E-X2D2-N (See note 3.)
E2E-X3D2-N (See note 3.)
E2E-X7D2-N (See note 3.)
E2E-X4MD2
E2E-X8MD2
E2E-X20MD2
1

Advertisement

loading

Summary of Contents for Omron E2E

  • Page 1 *1. In addition to the above models, E2E-X@@15 models (e.g., E2E-X3D15-N), which are different in frequency from the above models, are available. *2. E2E models with a robotics cable are available as well. The model number of a model with a robotics cable has the suffix “-R”...
  • Page 2 20 mm E2E-X20MD1-M1GJ *1. A model with no polarity has a residual voltage of 5 V, which must be taken into consideration together with the interface condition (the PLC’s ON voltage, for example) when connecting the Proximity Sensor to a load.
  • Page 3 PNP NC E2E-X18MF2 Note: 1. Cables with a length of 5 m are also available. Specify the cable length at the end of the model number (e.g., E2E-X2E1 5M). 2. Models with a robotics cable are also available. These models are E2E-X@E1-R (e.g., E2E-X5E1-R).
  • Page 4 NPN NC E2E-X2E2-M1 *1. These models do not conform to CE standards. *2. Cables with a length of 5 m are also available as standard models. Specify PNP NO E2E-X2F1-M1 the cable length at the end of the model number (e.g., E2E-X7T1 5M).
  • Page 5: Specifications

    3. The residual voltage of each E2E model with the model number suffix “-M1J-T” is 5 V. When connecting an E2E model with the suffix “-M1J-T” to a device, make sure that the device can withstand the residual voltage.
  • Page 6 2. When using an E2E with an M8 connector at an ambient temperature range between 70° C and 85° C, supply 10 to 30 VDC to the E2E and make sure that the E2E has a control output of 100 mA maximum.
  • Page 7 Note: 1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is over –25° C. 2. When using an M18-or M30-sized E2E within an ambient temperature of 70° C to 85° C, make sure that the E2E has a control output of 5 to 200 mA max.
  • Page 8 Accessories Instruction manual Note: 1. The response speed is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. 2. Power supply voltage waveform: Use a sine wave for the power supply. Using a rectangular AC power supply may result in faulty reset.
  • Page 9 Engineering Data Operating Range (Typical) Shielded Models E2E-X@D@ E2E-X@E@/F@ E2E-C@C@/B@ E2E-X@T1 E2E-X@Y@ E2E-X@C@/B@ E2E-X10 E2E-X10 E2E-X1/E2E-C1 E2E-X7 E2E-X3 E2E-X5 E2E-CR8 E2E-X2 E2E-X2 -X1R5 −3.0 −2.0 −1.0 −20 −15 −10 −5 −15 −10 −5 DistanceY (mm) Distance Y (mm) Distance Y (mm)
  • Page 10 Residual Output Voltage (Typical) E2E-X@T1 E2E-X@D@ 200 VAC 100 VAC E2E-X@D1-M1J-T 24 VDC E2E-X@D@ Load current (mA) Load current (mA) E2E-X@Y@ 100 VAC 24 VAC 200 VAC Residual output voltage Residual output voltage Residual output voltage Proximity Proximity Sensor Sensor...
  • Page 11 Sensing Distance vs. Sensing Object (Typical) E2E-X2D@ E2E-X3D@ E2E-X7D@ E2E-X3T1 E2E-X7T1 t = 1 mm t = 1 mm Iron Iron Stainless steel (SUS304) Iron Stainless steel (SUS304) Stainless steel Brass (SUS304) Brass Aluminum Brass Aluminum Copper Copper Aluminum t = 1 mm...
  • Page 12 E2E-X2E@/F@ E2E-X5E@/F@ E2E-X10E@F@ E2E-X2Y@ E2E-X5Y@ E2E-X10Y@ t = 1 mm Iron Iron Iron Stainless steel Stainless steel (SUS304) (SUS304) Stainless steel t = 1 mm (SUS304) Brass Brass Brass t = 1 mm Aluminum Aluminum Aluminum Side length of sensing...
  • Page 13 * Constant current output is 1.5 to 3 mA. ** When connecting to a Tr circuit. ** Pin 4 is an NO contact, and pin 2 is an NC contact. *** Pin 4 is an NO contact, and pin 2 is an NC contact.
  • Page 14 48 to 240 VAC Proximity sensor Power main supply circuit Blue Note: The load can be connected to either the +V or 0 V side. There is no need to be concerned about the polarity (Brown/Blue) of the Proximity Sensor. Inductive Sensors...
  • Page 15 Sensing object Setting indicator (green) Note: The diagnostic output of the E2E-X@D1S is ON when there is a coil burnout or the Operation sensing object is located in the unstable indicator (red) sensing range for 0.3 s or more. Control...
  • Page 16 Blue diagnostic output share the Blue negative common terminal. Therefore, the loads must be Note: There is no need to be connected to the positive Brown concerned about the polarity sides of the control output (Brown/Blue) of the and diagnostic output.
  • Page 17 (See note.) Load Note: Terminals 2 and 3 are not used. E2E-X@D1-M1J-T Load Load Note: 1. Terminals 1 and 2 are not used. 2. Terminals 3 and 4 has no polarity. E2E-X@D1-M1 Load Load Note: Terminals 1 and 2 are not used.
  • Page 18 E2E-X@E/F@-M@ DC 3-wire Models Connector Operation mode Applicable models Pin arrangement E2E-X@E1-M1 Load Note: Terminal 2 is not used. E2E-X@F1-M1 Note: Terminal 2 is not used. Load E2E-X@E2-M1 Load Note: Terminal 4 is not used. E2E-X@F2-M1 Note: Terminal 4 is not used.
  • Page 19 Pin arrangement M8-3pin NO/NC E2E-X1C@-M5 Load NO/NC E2E-X1B@-M5 Load E2E-X@Y@-M1 AC 2-wire Models Operation mode Applicable models Pin arrangement E2E-X@Y1-M1 Load Load Note: Terminals 1 and 2 are not used. E2E-X@Y2-M1 Load Load Note: Terminals 3 and 4 are not used.
  • Page 20 Note: The table below shows the tightening torques for part A and part B nuts. In the previous examples, the nut is on the sensor head side (part B) and hence the tightening torque for part B applies. If this nut is in part A, the tightening torque for part A applies instead.
  • Page 21 Mutual Interference When installing two or more Sensors face to face or side by side, ensure that the minimum distances given in the following table are maintained. Model Item E2E-X@D@ Shielded 20 mm 30 (20) mm 50 (30) mm 100 (50) mm...
  • Page 22 Wiring through Metal Conduit Do not use the Proximity Sensor in an environment with chemical If there is a power or high-tension line near the cable of the Proximity gas (e.g., strong alkaline or acid gasses including nitric, chromic, and Sensor, wire the cable through an independent metal conduit to pre- concentrated sulfuric acid gases).
  • Page 23 (1.3 mA) ≥ I 2. I (0.8 mA): OK leak 1. The ON voltage of the PLC and the residual voltage of the Prox- 3. I = [V (20.4 V) – V (3 V) –...
  • Page 24 Proximity Sensor B, Proximity Sensor B will not operate because the voltage imposed on Prox- imity Sensor B is 10 V, which is too low. When Prox- imity Sensor A is OFF, the voltage imposed on Proximity Sensor B will reach the supply voltage and Proximity Sensor B will be ON.
  • Page 25 E2E-X7D1-M1J-T (no polari- E2E-X10D1-M1J-T Note: 1. Two clamping nuts and one toothed washer are provided with M8 to M30 Models. 2. The model numbers of Pre-wired M8 to M30 Models are laser-marked on the milled section and cable section.
  • Page 26 The cable can be extended (separate metal The cable can be extended (separate metal conduit) conduit) up to 200 m (control output) or up to up to 200 m (control output) or up to 100 m 100 m (diagnostic output). (diagnostic output).
  • Page 27 (Conductors cross section: 0.3 mm , Insulator diameter: 1.3 mm), Toothed washer Standard length: 2 m The cable can be extended up to 200 m (separate metal conduit). Note: Operation indicator (red), setting indicator (green) Fig. 13 : E2E-X7D@-N/ Fig. 14 : E2E-X14MD@/...
  • Page 28 Two clamping nuts Toothed washre Toothed washer Toothed washer Note: D Models: Operation indicator (red), setting indicator (green) Note: D Models: Operation indicator (red), setting indicator (green) E, F Model: Operation indicator (red) E, F Model: Operation indicator (red) Fig. 19 : E2E-X3D@-M1(G) Fig.
  • Page 29 Two clamping nuts Two clamping nuts Toothed washer Toothed washer Note: D models: Operation indicator (red), setting indicator (green) Note: D models: Operation indicator (red), setting indicator (green) E, F model: Operation indicator (red) E, F model: Operation indicator (red) Pre-wired M12 Connector Models Fig.
  • Page 30 Pre-wired M12 Connector Models Fig. 33 : E2E-X14MD1-M1GJ 29 dia. M12 × 1 14.8 dia. Operation indicator (red), 6-dia. round cable, M18 × 1 Standard length: 0.3 m setting indicator (green) Two clamping nuts Toothed washer Fig. 34 : E2E-X10D1-M1GJ...
  • Page 31 Warranties and Limitations of Liability WARRANTY OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABI- LITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS.
  • Page 32 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. Cat. No. D058-E2-03-X Inductive Sensors...