Omron SYSMAC C200H-IDS01-V1 Operation Manual page 35

Id sensor
Hide thumbs Also See for SYSMAC C200H-IDS01-V1:
Table of Contents

Advertisement

The User Program
Write Command
Specifies the type of
data to be written,
which can be ASCII
characters or hexadeci-
mal numbers. Code A
(41) specifies ASCII
characters, while H (48)
specifies hexadecimal
numbers.
20
This command writes data to the internal memory of the Data Carrier. Up to
1024 bytes (512 words) of data can be written per scan. Specify the first
address in hexadecimal.
15
00
W
T
5
7
5
4
A/H
1
41/48
3
1
*
2
A
0
D
This is OP (operation) code indicating
that the command is Write.
This is OP code represented in
ASCII code.
This code selects a Read/Write Head
and is always fixed to 1.
ASCII code
Specifies the first address of the Data
Carrier memory to which data is to be
written. Addresses $0000 through
$FFFF can be specified in hexadeci-
mal.
Write data
1024 bytes max. = 512 words
Terminator
ASCII code
Section 2-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysmac c200h-ids21

Table of Contents