Timing Considerations

If an er-
ror did
not occur
RESET

3-2-10 Error Codes

3-3

Timing Considerations

3-3-1

Command Processing Time

C200H-IDS01-V1
6,000
4,000
2,000
1,000
600
400
200
100
60
40
20
10
1 2
70
STA.ERRORS INF.
NO ERROR
HEAD 1 PAGE 1
STadrs1F data 29
Error code
number
70
71
72
7A
7C
7D
This section covers command processing time, which is the time required for
data communication between the Data Carrier and ID Sensor Unit; and turn-
around time, which is the time required by the PC to retrieve a command and
complete the reading/writing of data from/to the Data Carrier.
Use the following table and graph to calculate the amount of time required for
executing commands involving data communication between the ID Sensor
Unit and Data Carrier.
Command Processing Time is the time required for data communication
between the CPU, ID Sensor, and Data Carrier.
The following graphs show the relationship between the quantity of data to be
processed and the time required for processing a command.
4 6 10
20
40 60100 200
Amount of data (bytes)
If no errors have occurred, this mes-
sage will be displayed.
To start another operation or abort
the Error Log operation, press the
RESET key and the display will
return to reset status.
Error name
Data carrier communicatin error
Data verification error
No Data Carrier error
Data Carrier address error
Read/Write Head (or Antenna) disconnect error
Wrire protect error
C200H-IDS21
6,000
4,000
2,000
1,000
600
400
200
100
60
40
20
10
1,000
1 2
4 6 10
20
40 60100 200
Amount of data (bytes)
Section 3-3
Error message
COM.DC E
VERIFY E
NO DC E
ADRS E
R/W H E
PROTCT E