Omron SYSMAC C200H-IDS01-V1 Operation Manual page 61

Id sensor
Hide thumbs Also See for SYSMAC C200H-IDS01-V1:
Table of Contents

Advertisement

Program Examples
Program Example 7:
Calculation and Writing of Data Carrier's Data Check Code
Command
10400
execution input
ID busy
10906
10906
10400
10908
Command Data in the CPU
15
DM 0800
4D
DM 0801
4B
DM 0802
00
DM 0803
00
DM 0804
2A
46
MOV(21)
#0005
101
MOV(21)
#0800
102
10906
10000
DIFD(14)
10908
ANDW(34)
104
#FF00
DM0810
CMP(20)
DM0810
#0000
25506
10907
Equal flag
00
44
31
10
20
0D
Sets the number of words in the command data to 5
words.
Sets the beginning word where the command data is stored to DM
0800.
Holds the status until the ID Sensor Unit begins executing the com-
mand.
Command execution flag
Processing end
Judges the result of processing
Command error output
Data in the Data Carrier
Address
7
000F
0010
0011
0012
Calculation object
002D
002E
Check code
002F
0030
0
Check area
Section 3-1