ZyXEL Communications MGS-3712F User Manual page 41

Metrogigabit switch
Hide thumbs Also See for MGS-3712F:
Table of Contents

Advertisement

Insert the alarm connector into the Signal slot.
3
Figure 15 Connecting a Sensor to the Signal Slot
Door Open
Sensor
Signal
Connector
To connect an output device, repeat the previous steps but this time connect to
4
either pins (1,2) or (2,3) on the Signal connector.
You can also daisy-chain the external alarm to another ZyXEL Switch which
supports the external alarm feature. If daisy-chaining to a ZyXEL switch that is a
different model, check your switch's documentation for the correct pin
assignments.
Use wires of the correct gauge to connect either of the signal output pin pairs (1-
1
normal close, 2-common) or (2-common, 3-normal open) on the Signal
connector to the input signal pin pairs of an Signal connector on another ZyXEL
Switch.
MGS-3712/MGS-3712F User's Guide
11 10
10
9
8
7
6
Signal Input Pins
(Dry contact,
normal open only)
Chapter 3 Hardware Overview
Spring
Clip
5
4
3
2
1
Signal
Output
Pins
41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mgs-3712

Table of Contents