Brocade Communications Systems Brocade 8/12c Reference page 231

Brocade fabric os mib reference supporting fabric os v7.0.0 (53-1002151-01, april 2011)
Hide thumbs Also See for Brocade 8/12c:
Table of Contents

Advertisement

Object and OID
connUnitPortStatus
1.3.6.1.3.94.1.10.1.7
connUnitPortTransmitter
Type
1.3.6.1.3.94.1.10.1.8
connUnitPortModuleType
1.3.6.1.3.94.1.10.1.9
Fabric OS MIB Reference
53-1002151-01
Access
Description
Read only
An overall protocol status for the port. For a U_Port, the status should be
ols (9).
Possible values are:
unknown (1)
unused (2) - Device cannot report this status.
ready (3) - FCAL Loop or FCPH Link reset protocol initialization has
completed.
warning (4) - Do not use.
failure (5) - Port is faulty.
notparticipating (6) - Loop not participating and does not have a
loop address. Do not use.
initializing (7) - Protocol is proceeding. Do not use.
bypass (8) - Do not use.
ols (9) - FCP offline status. (Not supported in Fabric OS v2.6.1.)
NOTE: In Fabric OS v2.6.x, for an E_Port, F_Port, or FL_Port, the value is
3 (ok). For a U_Port, the value is 2 (unused) if not faulty with
GBIC, 1(unknown) if not faulty but no GBIC, or 5 (failure) if faulty.
In Fabric OS v3.x and later, for an E_Port, F_Port, FL_Port or
other Port and online port state, the value is 3 (ok). For G_Port or
other Port and offline port state, the value is 9 (ols). For
unknown portype and offline port state, the value is 1
(unknown).
Read only
The technology of the port transceiver.
Possible values are:
unknown (1)
other (2)
unused (3)
shortwave (4)
longwave (5)
copper (6)
scsi (7)
longwaveNoOFC (8)
shortwaveNoOFC (9)
longwaveLED (10)
ssa (11) (Not supported in Fabric OS v2.6.1.)
For an external FC port, this value should be 9 (shortwaveNoOFC), 8
(longwaveNoOFC), or 6 (copper).
Read only
The module type of the port connector.
Possible values are:
unknown (1)
other (2)
gbic (3)
embedded (4) Fixed (oneXnine)
glm (5)
gbicSerialId (6)
gbicNoSerialId (7)
gbicNotInstalled (8)
smallFormFactor (9)
For an external FC port with GBIC, this value is set to 6 (gbicSerialId) or 7
(gbicNoSerialId). For an external FC port without GBIC, this value is set to
8 (gbicNotInstalled).
Connectivity unit group
9
211

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.0.0

Table of Contents