Trunking Group - Brocade Communications Systems Brocade 8/12c Reference

Brocade fabric os mib reference supporting fabric os v7.0.0 (53-1002151-01, april 2011)
Hide thumbs Also See for Brocade 8/12c:
Table of Contents

Advertisement

6

Trunking group

Object and OID
swBlmPerfEEDid
1.3.6.1.4.1.1588.2.1.1.1.23.2.
1.7
swBlmPerfFltMntTable
1.3.6.1.4.1.1588.2.1.1.1.23.3
swBlmPerfFltMntEntry
1.3.6.1.4.1.1588.2.1.1.1.23.3.
1
swBlmPerfFltPort
1.3.6.1.4.1.1588.2.1.1.1.23.3.
1.1
swBlmPerfFltRefkey
1.3.6.1.4.1.1588.2.1.1.1.23.3.
1.2
swBlmPerfFltCnt
1.3.6.1.4.1.1588.2.1.1.1.23.3.
1.3
swBlmPerfFltAlias
1.3.6.1.4.1.1588.2.1.1.1.23.3.
1.4

Trunking group

Object and OID
swTrunk
1.3.6.1.4.1.1588.2.1.1.1.24
swSwitchTrunkable
1.3.6.1.4.1.1588.2.1.1.1.24.1
swTrunkTable
1.3.6.1.4.1.1588.2.1.1.1.24.2
swTrunkEntry
1.3.6.1.4.1.1588.2.1.1.1.24.2.
1
168
Access
Description
Read only
Gets SID information by reference number. SID (Source Identifier) is
a 3-byte field in the frame header used to indicate the address
identifier of the N_Port from which the frame was sent.
Not
Filter-based monitoring counter.
accessible
To configure the predefined monitors on port, use the fmmonitor
--addmonitor <frame_type> -port <slot/port_list> command.
To configure the user-defined monitors on port, use one of the
following commands:
fmmonitor --create <frame_type> -pat <bitpattern> [-port
<slot/port_list>]
fmmonitor --addmonitor <frame_type> -port <slot/port_list>
Not
Filter-based monitoring counter for given port.
accessible
Read only
This object identifies the port number of the switch.
Read only
This object identifies the reference number of the filter. This
reference number is assigned when a filter is created. In the SNMP
Index, start with one instead of 0, add one to actual reference key.
Read only
Get statistics of filter-based monitor. Filter-based monitoring
provides information about a filter hit count, such as:
Read command
SCSI or IP traffic
SCSI Read/Write
Read only
Alias name for the filter.
Access
Description
Not
The OID sub-tree for swTrunk group.
accessible
Not
This object indicates whether the switch supports the trunking
accessible
feature or not:
no (0)
yes (8)
Not
This object displays trunking information for the switch.
accessible
For the Brocade 4100, cc ports per trunk are supported.
Not
Entry for the trunking table.
accessible
Fabric OS MIB Reference
53-1002151-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.0.0

Table of Contents